Iron Deficiency Profile with Ferritin (5 Tests)
Test Information
Also Known As
* Iron Status Panel with Ferritin
* Comprehensive Iron Panel
* Iron Indices with Ferritin
* Ferritin and Iron Profile
* Iron Metabolism Test
* Iron Studies 5 Parameters
Test Parameters Included
- Iron Level (Serum Iron)
- Total Iron Binding Capacity (TIBC)
- Transferrin by Immunoturbidimetry
- Transferrin % Saturation
- Ferritin
- TEST PARAMETERS EXPLAINED:
- Iron Level (Serum Iron): Measures the amount of iron circulating freely in the blood. This iron is typically bound to transferrin.
- Total Iron Binding Capacity (TIBC): Measures the total amount of iron that can be bound by proteins in the blood, primarily transferrin. It reflects the total number of available binding sites on transferrin.
- Transferrin by Immunoturbidimetry: Directly measures the concentration of transferrin protein in the blood. Transferrin is the main protein responsible for transporting iron in the bloodstream.
- Transferrin % Saturation: Represents the percentage of transferrin that is actually bound with iron. It's a calculated value that provides insight into how much iron is available for use by the body.
- Ferritin: Measures the amount of ferritin, a protein that stores iron inside cells. It reflects the body's total iron stores.
Department
Methodology
* Principle: Serum iron is released from its binding proteins (transferrin) under acidic conditions. This iron (usually in the ferric, Fe3+, form) is then reduced to ferrous iron (Fe2+). The ferrous iron then reacts with a chromogen (a colored complex-forming agent, e.g., ferrozine or bathophenanthroline) to form a colored complex.
* Measurement: The intensity of the color produced is directly proportional to the concentration of iron in the sample. This intensity is measured by a spectrophotometer, which passes a specific wavelength of light through the sample and measures the amount of light absorbed. The absorbance is then converted to an iron concentration using a calibration curve.
* Total Iron Binding Capacity (TIBC): Spectrophotometry
* Principle: Excess iron (usually ferric iron) is added to the serum sample to saturate all available binding sites on transferrin. Unbound, excess iron is then removed (e.g., by precipitation or adsorption). The iron that remains bound to transferrin is then released and measured spectrophotometrically using the same principle as for serum iron.
* Transferrin by Immunoturbidimetry: Immunoturbidimetry
* Principle: This method quantifies specific proteins (like transferrin) in a sample. When specific antibodies (anti-transferrin antibodies) are mixed with the patient's serum containing transferrin, they bind to the transferrin molecules, forming insoluble antigen-antibody complexes. These complexes cause the solution to become turbid (cloudy).
* Measurement: A spectrophotometer measures the increase in turbidity (light scattering) of the solution. The degree of turbidity is directly proportional to the concentration of transferrin in the sample. This allows for a precise and automated measurement of transferrin levels.
* Transferrin % Saturation: Calculated Value
* Formula: Transferrin % Saturation = (Serum Iron / TIBC) x 100
* This calculation uses the measured serum iron and TIBC values to provide a percentage indicating how much of the total iron-binding capacity of transferrin is actually occupied by iron. It's a key indicator of iron status.
* Ferritin: Immunoturbidimetry (or other immunoassay methods like ELISA, Chemiluminescence)
* Principle: Similar to transferrin, but specifically for ferritin protein. Anti-ferritin antibodies are used to react with ferritin in the sample, forming immune complexes that cause turbidity.
* Measurement: The turbidity (or light scattering) is measured spectrophotometrically, and the concentration of ferritin is determined from a standard curve.
Sample Required
* Collection: Blood is drawn by venipuncture, typically from an arm vein. * Tube Type: Collected in a plain red-top tube or a serum separator tube (SST) with gel. * Volume: Approximately 1 mL of serum is required, meaning a larger volume of whole blood (e.g., 3-5 mL) must be collected to yield 1 mL of serum after clotting and centrifugation. * Processing: The blood sample should be allowed to clot at room temperature, then centrifuged to separate the serum. * Storage: Serum should be promptly separated from cells to prevent the release of iron from red blood cells. If not tested immediately, serum can be refrigerated (2-8°C) for a short period (e.g., up to 24-48 hours) or frozen (-20°C or colder) for longer storage.
Preparation
Schedule Report
12 Hours
Emergency Report
Yes
Frequently Asked Questions
Why do I need to fast before this test?
Fasting for 8-12 hours is usually required because food intake, especially iron-rich foods, can temporarily affect your serum iron levels, leading to inaccurate results.
What is the difference between iron and ferritin?
Serum iron measures the iron currently circulating in your blood. Ferritin is a protein that stores iron, so it reflects your body's overall iron reserves. Low ferritin is the most sensitive indicator of iron deficiency.
What does high ferritin mean?
High ferritin can indicate iron overload (too much iron in the body), but it can also be elevated due to inflammation, infection, liver disease, or certain cancers, even if iron stores aren't excessively high. Your doctor will interpret it with other parameters.
What does low transferrin saturation mean?
Low transferrin saturation means that a smaller percentage of the iron-carrying protein (transferrin) is actually carrying iron. This is a strong indicator of iron deficiency.
Can medications affect my iron profile results?
Yes, certain medications like iron supplements, multivitamins containing iron, and some other drugs can influence your iron levels. Always inform your doctor about all medications you are taking.
What is TIBC?
TIBC stands for Total Iron Binding Capacity. It measures the total amount of iron that proteins in your blood (mainly transferrin) are capable of carrying. It helps assess how well iron is transported in your body.
How is transferrin measured by immunoturbidimetry?
In immunoturbidimetry, specific antibodies are added to your serum. These antibodies bind to transferrin, forming complexes that make the solution cloudy. The cloudiness is measured by a machine to determine the transferrin concentration.
How quickly will I get my results?
Your results will typically be available within 12 hours.
If my iron levels are abnormal, what should I do?
Abnormal results require consultation with your doctor. They will interpret the entire panel in the context of your symptoms and medical history and recommend appropriate further steps, which might include dietary changes, supplements, or further investigations.
Is this test suitable for diagnosing anemia?
This test is crucial for diagnosing iron deficiency anemia and distinguishing it from other types of anemia. However, a Complete Blood Count (CBC) is usually done alongside this test to fully characterize the anemia.
Test Description
Test Code
PI1
Recommended Addons
- High-end laboratory & medical equipment.
- Outstanding doctor team.
- Personalized care & high-quality service.
- Tailormade health screening packages.