Test
Sample: UrineNo Fasting RequiredLab / Home CollectionReport: 72 Hours (3 Days)

Aerobic C&S Urine Culture and Sensitivity AUTOMATED - MIC

₹2,000 ₹1,499
Save 25%

Test Information

Also Known As

No data available

Test Parameters Included

  • Colony Forming Units per milliliter (CFU/mL) - quantitative bacterial load
  • Pathologist Microbiology Remark - antimicrobial susceptibility profile with MIC values for each tested agent
Read more

Department

MICROBIOLOGY

Methodology

Automated Culture and Susceptibility Testing (MIC)
This test utilizes an Automated Culture and Susceptibility Testing system. The process involves:
* Automated Inoculation: The urine sample is automatically inoculated onto appropriate culture media (e.g., Blood Agar, MacConkey Agar) using calibrated loops to ensure a standardized quantity of urine is plated. This allows for semi-quantitation of bacterial growth.
* Automated Incubation: The inoculated plates are then automatically transferred to an incubator at a specific temperature (typically 35-37°C) for a defined period (usually 18-24 hours).
* Automated Growth Detection & Colony Counting: After incubation, automated systems (e.g., using imaging technology) detect and count bacterial colonies, identifying significant bacteriuria based on pre-defined colony forming unit (CFU) thresholds (e.g., \\ge 10^5 CFU/mL for uncomplicated UTIs, lower thresholds for catheterized patients or specific clinical contexts).
* Automated Identification (ID): If significant growth is detected, the system automatically isolates pure colonies and performs rapid biochemical or mass spectrometry (e.g., MALDI-TOF) tests to identify the specific bacterial species (e.g., Escherichia coli, Klebsiella pneumoniae, Proteus mirabilis).
* Automated Susceptibility Testing (AST) - MIC: Once the bacteria are identified, the automated system prepares a standardized bacterial suspension and performs susceptibility testing. This involves exposing the bacteria to various concentrations of different antibiotics. The system then measures the Minimum Inhibitory Concentration (MIC) for each antibiotic. The MIC is the lowest concentration of an antibiotic that prevents visible growth of the bacterium.
* Automated Interpretation: The MIC values are then automatically interpreted by the system (based on established clinical breakpoints from organizations like CLSI - Clinical and Laboratory Standards Institute) to determine if the isolate is Susceptible (S), Intermediate (I), or Resistant (R) to each tested antibiotic.
This automated approach offers rapid, standardized, and highly accurate results for both bacterial identification and antibiotic susceptibility, crucial for guiding effective antibiotic therapy.
Read more

Sample Required

Urine (Mid-Stream Clean Catch or Catheterized)
* The preferred sample type is a mid-stream clean-catch urine specimen to minimize contamination from the skin and urethra. Patients are provided with clear instructions on how to collect this specimen.
* For hospitalized or specific patient populations, a catheterized urine specimen may be collected.
* First-morning urine is often preferred as it is more concentrated and likely to yield organisms if present.
* Minimum volume: Typically 5-10 mL of urine is sufficient.
* Sterile container: Urine must be collected in a sterile, leak-proof container.
* Timely transport/refrigeration: The specimen should be transported to the laboratory immediately or refrigerated (4°C) for up to 24 hours to prevent overgrowth of contaminants or degradation of pathogens.
Read more

Preparation

Proper collection and timely transport of the urine sample are paramount for accurate results to avoid contamination and bacterial overgrowth.
* Patient Instructions: Provide the patient with clear, detailed instructions for collecting a mid-stream clean-catch urine specimen. This usually involves:
* Washing hands thoroughly.
* Cleaning the genital area with antiseptic wipes (front to back for females).
* Beginning to urinate into the toilet.
* Collecting the "middle" portion of the urine stream into the sterile container without touching the inside of the container.
* Finishing urination into the toilet.
* For Catheterized Patients: The specimen should be collected aseptically from the catheter port (not the drainage bag).
* Container: Use a sterile, leak-proof, screw-cap urine collection container.
* Labeling: Clearly label the container with the patient's full name, date of birth, date, and time of collection.
* Timely Transport/Refrigeration: The sample should be sent to the laboratory as soon as possible (ideally within 1 hour). If immediate transport is not possible, the sample must be refrigerated at 2-8°C for up to 24 hours to prevent bacterial multiplication and false positive results.
Read more

Schedule Report

72 Hours (3 Days)

Emergency Report

Yes

Frequently Asked Questions

Why is a mid-stream clean-catch urine sample preferred?

It minimizes contamination from skin and urethral flora, ensuring the cultured organism truly represents a urinary tract infection rather than a sample collection artifact.

What does CFU/mL mean in a urine culture report?

Colony Forming Units per milliliter indicates the concentration of bacteria growing from the urine sample. A count of 10^5 CFU/mL or higher is generally considered significant for urinary tract infection.

How long does it take to get C&S urine culture results?

Initial culture results are available within 24 hours, while full susceptibility and MIC reporting typically takes 48 hours.

What does the sensitivity report tell the doctor?

It shows which antibiotics effectively inhibit or kill the isolated bacteria, helping the physician prescribe the most targeted and effective antimicrobial therapy.

Can antibiotics before the test affect the culture result?

Yes, prior antibiotic use can suppress bacterial growth and lead to a false-negative culture. Inform your doctor if you have recently taken any antibiotics.

Do I need to fast before providing a urine sample?

No fasting is required for a urine culture and sensitivity test. Drink adequate water to ensure an adequate urine sample can be collected.

Read more

Test Description

Aerobic C&S Urine Culture and Sensitivity AUTOMATED - MIC Examination Test Overview The Aerobic C&S Urine Culture Automated - MIC test identif... Read more

Test Code

C61

Book This Test

Share this test

  • High-end laboratory & medical equipment.
  • Outstanding doctor team.
  • Personalized care & high-quality service.
  • Tailormade health screening packages.
T&C